  1. www.trox.de › en › fire-dampersFK2-EU | TROX GmbH

    Combined installation with FKRS-EU and FKR-EU in solid walls and ceiling slabs, lightweight partition walls, shaft walls as well as timber stud walls and half-timbered constructions up to 1.2 total fire damper surface area; 2 inspection access panels Ø110 mm, with bayonet fixing (can be opened without tools)

  2. www.troxuk.co.uk › fire-dampers › tq2-installation-kits-for-fkrs-eu-5c69ec28082834e0TQ2 Installation Kits for FKRS-EU | TROX UK Ltd

    Small circular fire damper for shutting off air ducts between 2 fire compartments, available in 10 nominal sizes. Nominal sizes: 100 – 315 mm; Low differential pressure and sound power level; Explosion-proof construction (ATEX) as an option; Optional use as upstream shutter of an air transfer unit; Optional use as air transfer damper

  3. Fire dampers with installation subframe and installation kit only in casing length L = 500 mm. The installation subframe and the fire damper with installation kit must be installed and attached according to the operating and installation manual.

  4. www.trox.ae › fire-dampers › fka2-eu-3f5a2bfabe8cfb75FKA2-EU - TROX

    In the event of a fire, fire dampers shut automatically to prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments. In the event of a fire, the damper is triggered at 72 °C or at 95 °C (use in warm air ventilation systems) by a fusible link.

  5. The installation kit must be fitted to the fire damper on site, see installation and operating instructions FKA2-EU. Enough clear space is required for mounting the installation kit onto the fire damper. The ES installation kit is fastened using drywall screws (diameter) 5.5 mm and flange angles. Use dry wall screws that are long enough.

  6. Safety notes Symbols are used in this manual to alert readers to areas of potential hazard. Signal words express the degree of the hazard. Comply with all safety instructions and proceed carefully

  7. www.trox.de › en › fire-dampersFK2-EU H - trox.de

    In the event of a fire, fire dampers shut automatically to prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments. In the event of a fire, the damper is triggered at 72 °C or at 95 °C (use in warm air ventilation systems) by a fusible link.