  1. 17 Αυγ 2020 · Minimum Condensate Drain Pipe Sizing Chart. Slope to be at least 1/8” per foot or 1 percent, that is for every 12” horizontally there must be at least an 1/8” drop vertically. Condensate drain piping to slope a minimum of 1/8″ per every 12″ horizontal.

  2. the condensate drain line slope towards its final drainage point shall be at 1/8" per foot [or, of course greater, where vertical drains are used - Ed.] OPINION: your local building code compliance inspector/officer is the final legal authority on HVAC condensate drain trap requirements.

  3. condensate lines. . Horizontal with clear—and also Grade – No Slope helps prevent corrosion and water hammer. Pitch. All steam distribution lines should be installed with a correct slope.

  4. The IMC dictates a 1% minimum pitch of the drain, equal to 1/8″ fall for every 12″ (foot) of horizontal run. In practice, it is safer to use 1/4″ of fall per foot to ensure proper drainage and provide some wiggle room for error.

  5. A guide to sizing condensate lines to and from steam traps, including examples and calculations using the condensate pipe sizing chart.

  6. 24 Μαΐ 2023 · A condensate drain line is a component of an HVAC system that removes the moisture (condensate) that is generated during the cooling process. When warm air passes over the evaporator coils in the air conditioning unit, the moisture in the air condenses on the coils, creating water droplets.

  7. 5 Φεβ 2024 · Table of Contents. What is a Condensate Drain Line? AC Condensate Drain Line Size and Types. Installing Condensate Drain Lines. Condensate Traps and Safety Switches. Maintenance of Condensate Drain Lines. How to Unclog an AC Condensate Drain Line. Preventing Common Issues with Condensate Drain Lines. Conclusion. What is a Condensate Drain Line?