7 Νοε 2003 · We choose the wedge versus the expansion bolt system for three reasons. 1. If the expansion bolt installer is not careful when inserting the expansion bolt, it is possible for the wedge sleve to be slipped up the bolt and never actually engage properly. This conditions can be difficult to detect until investigation after a failure.
13 Ιουλ 2020 · The cantilever is 60" projected (cantilevered canopy outriggers) spacing = 48". cantilever HSS 3" x 1/2" x 1/4". End plate fillet welded at the end of HSS 8" x 6" x 3/4". Main HSS Beam is 12" x 6" x 3/8”. Main beam is existing and the outriggers will be fabricated in the warehouse. GC_Hopi (Structural) 13 Jul 20 19:07.
6 Οκτ 2015 · An anchor is a general term used to fasten to concrete. An expansion bolt is a torque-controlled fastener. It screws into an insert that expands. Hilti Kwik Bolt TZ are common. An epoxy adhesive anchor, or chemical, is basically glued to the concrete. Hilti HIT-HY 200 is common. As for the anchor that you select, point it out to your reviewer.
One reason for greater clearance on larger bolts is that larger bolts are used on larger assemblies (in many cases). Large assemblies are often heavy and unwieldy, making it harder to put them together. A little more slop in the clearance holes often goes a long way toward making it easier to put such things together.
15 Απρ 2002 · Assume an expansion bolt connects something to a concrete foundation wall and is loaded in shear PARALLEL to the wall, with plenty of concrete in either direction parallel to the wall. Assume the expansion bolt is close to the edge of the wall in the PERPENDICULAR direction. Should the...
23 Ιουλ 2003 · I have a problem where some anchor rods are located in the wrong spot. Instead of cutting off the base plate and re-welding would it be possible to use an expansion anchor (25mm diameter) 70mm away from the existing anchor rod and cut off the existing rods? The existing the bolts have loads that are 2.25 k tension and .16 k shear.
31 Οκτ 2015 · When installed under base plate: When you use 16mm lag screw, the housing that needs to get inside or drilled must be 22mm.. so when you insert the housing inside, there is a gap between the bolt insert and surrounding concrete (22mm-16mm= 8mm) on the upper part.. only the bottom is in contact.. how does the tension breakaway mechanism of this ...
Structural. May 14, 2009. 594. US. One more benefit to epoxy over expansion ("wedge"): With epoxy, you can use 316 stainless steel threaded rod. Some of the wedge anchors that have been certified for "cracked concrete" are 304, but not 316.
Structural. Sep 24, 1999. 16,336. US. J-bolts and L-bolts can pull out before concrete failure occurs. This is a disadvantage. Using a straight bolt with a plate on the end develops a good shear cone and high strength, provided they are placed such that the reinforcing steel intersects the stress development area.
10 Μαΐ 2007 · Look at the allowable stress value for the temperatures that you specified. At 800 deg F the allowable stress value between the B7 and B16 is small. However, at the 1000 deg F the allowable stress values are nearly 2.5 times higher for the B16 as compared to the B7. Therefore, at the elevated temperatures above 800 deg F the B16 is a more ...